Home › 20E049000
Loss of Drive from Fractured Pressure Switch
Allison Transmission, Inc.NHTSA recall 20E049000Jul 17, 2020
Fix announcedDealer or service repair
50% of affected vehicles repaired so far, per the automaker's latest quarterly report to NHTSA
Vehicles included
This is an equipment recall: NHTSA lists the products, not vehicles. See NHTSA's page below.
Questions about this recall
- ATI customer service: 1-317-242-5000
Numbers as given in the recall filing. NHTSA's Vehicle Safety Hotline: 1-888-327-4236.
What NHTSA says
The problem
Allison Transmission, Inc. (ATI) is recalling certain Drive Units: H 50 EP (part numbers 29540673 and 29540900), H 40 EP (part numbers 29540697 and 29549708), H 50 EP Cert (part numbers 29556925 and 29556926), and H 40 EP Cert Drive (part numbers 29557038 and 29557036). The pressure switches on these Drive Units may fail, possibly resulting in a loss of drive.
What can happen
A loss of drive can disable the vehicle unexpectedly, increasing the risk of a crash.
The fix
ATI will notify the manufacturers that purchased the affected equipment, and ATI dealers will replace the C1 and C2 pressure switches in the affected drive units free of charge. The recall began August 10, 2020. Owners may contact ATI customer service at 1-317-242-5000.
- NHTSA recall number
- 20E049000
- Received by NHTSA
- Jul 17, 2020
- Filed by
- Allison Transmission, Inc.
- Vehicles or items affected
- 262
- Part
- Power train
- Automaker's recall number
- NR (Not Reported)
- Repaired so far
- 50% of affected vehicles, per the automaker's latest quarterly report to NHTSA