Vehicle Bulletin

Home › 08E047000

T-14 SERVICE BRAKE CHAMBER

BENDIX SPICER FOUNDATION BRAKE LLCNHTSA recall 08E047000Aug 7, 2008

Fix announcedRepair type unclear

Vehicles included

This is an equipment recall: NHTSA lists the products, not vehicles. See NHTSA's page below.

What NHTSA says

The problem

BENDIX IS WORKING WITH THE VEHICLE MANUFACTURERS TO RECALL 353 BENDIX T-14 SERVICE BRAKE CHAMBERS USED ON SOME BENDIX ADB22X AIR DISC BRAKES TO BE INSTALLED ON STEER AXLES OF SOME TRUCKS. THE LUBRICANT USED AS AN ASSEMBLY AID FOR THE T-14 SERVICE CHAMBERS DOES NOT EVAPORATE AS INTENDED AND CAN MIGRATE BETWEEN THE PUSHROD BASE AND THE RUBBER DIAPHRAGM. THIS CAN CAUSE THE PUSHROD BASE TO BECOME MISALIGNED AND LODGED IN THE CHAMBER BODY AFTER A BRAKE APPLICATION, RESULTING IN THE BRAKE NOT FULLY RELEASING.

What can happen

IF A BRAKE ON THE STEER AXLE REMAINS PARTIALLY APPLIED, VEHICLE STEERING ABILITY AND STABILITY CAN BEAFFECTED ON SLIPPERY ROAD SURFACES, POSSIBLY RESULTING IN A VEHICLE CRASH.

The fix

EACH VEHICLE MANUFACTURER WILL PROVIDE A REMEDY PLAN AND NOTIFICATION SCHEDULE. THE AFFECTED VEHICLES WILL BE REPAIRED WITHOUT CHARGE TO THE OWNERS. THE RECALL BEGAN ON JULY 22, 2008. OWNERS MAY CONTACT THEIR VEHICLE MANUFACTURER OR BENDIX TOLL-FREE AT 1-866-610-9709.

NHTSA recall number
08E047000
Received by NHTSA
Aug 7, 2008
Filed by
BENDIX SPICER FOUNDATION BRAKE LLC
Vehicles or items affected
181
Part
Service brakes, air
Automaker's recall number
NR (Not Reported)

This recall on NHTSA.gov