- Stabilizer Beam Welds May Crack
May 31, 202313 vehicles92.3% repaired so far
Iowa Mold Tooling., Inc. (IMT) is recalling certain IMT Hydraulic Loaders model, 50-345, part number, 6390121. The stabilizer beams may have welds that crack over time and break under load.
- Stabilizer Beam Welds May Crack Over Time
Aug 15, 202231 vehicles100% repaired so far
Iowa Mold Tooling Co., Inc. (IMT) is recalling certain Hydraulic Loaders, model 42684 and part number 6390121. The welds on the stabilizer beams may crack over time, or break under load.
- Transmitter Failure Causing Crane Movement
Nov 16, 201820 vehicles60% repaired so far
Iowa Mold Tooling Co., Inc. (IMT) is recalling certain Omnex Proportional Wireless Transmitters, part numbers 70733882 and 70733883, used for controlling cranes. These wireless transmitters…
- Stabilizer Pin Locking Arm Pin Incorrect
Nov 13, 201719 vehicles57.9% repaired so far
Iowa Mold Tooling Co., Inc. (IMT) is recalling certain Dominator I Crane bodies sold for installation onto other chassis. These cranes have incorrect stabilizer arm locking pins that may…
- Valve Bank Cover May Crack and Detach
Feb 17, 20161,598 vehicles53.3% repaired so far
Iowa Mold Tooling Co., Inc. (IMT) is recalling certain Series III Cranes, models 6000, 7500, 8600, 9500, 10000, 12000, and 14000, manufactured April 4, 2013, to January 22, 2016. The…